Are metal rupture discs outside of the scope of NACE MR0175-ISO 15156?

14th March 2016

Viewed 3212 Times

Question: Using NACE MR0175-ISO 15156-1, Clause 5, Paragraph 9 and NACE Interpretation MP INQUIRY #2009-05 Part 1 as references. Based on the fact that most metal rupture discs are plastically deformed during manufacturing and all metal rupture discs plastically deform when they burst, are metal rupture discs outside of the scope of NACE MR0175-ISO 15156?

Answer:

No. Permitted exclusions are listed in ISO 15156-1 Table 1. When ISO 15156 is specified, components, including rupture discs, must comply with the materials and conditions listed in the standard or qualified in accordance with Annex B.

This question is in relation to NACE MR0175/ISO 15156-1 Clause 5

Reference: ISO 15156 Maintenance Panel Inquiry #2011-08

At Oil & Gas Corrosion can help you with NACE MR0175 compliance.

 

With a wealth of experience in the oil and gas industry, we provide independent materials and corrosion consultancy to help companies reduce risk, save money and apply best practice in their oil and gas businesses.

Find out more by getting in touch – you’ll get an answer from a qualified, experienced materials engineer every time.

How to get in touch

  Email Us

USA toll-free

Live Chat

US: 877-399-1010 (toll free)
UK: +44(0)1144000850

Sheffield Office
Smithfield
Sheffield
S3 7AR
United Kingdom

Was this answer helpful ? Yes / No

Blog

Consultoría Técnica para la norma NACE MR0175 en español

17th August 2019

...
READ

My summer at Oil and Gas Corrosion Ltd as an intern.

16th August 2019

...
READ

NACE MR0175 / ISO 15156 Technical Circulars for Part 2 and 3 published 2019-05-29

30th May 2019

...
READ

What is the difference between NACE MR0175 and NACE MR0103? Get an answer from our expert team!

1st February 2019

...
READ

Users of BP Cassandra excel file have migrated to cloud solutions.

23rd January 2019

...
READ

How to use NORSOK M-506 Edition 3: 2017 to calculate corrosion rate?

4th January 2019

...
READ

View BLOG ➤

Tweets

  • Partial pressure of H2S, design or operation conditions? Talk to our team, we have the technical author... https://t.co/YquGn6u3FJ, 8 hours ago
  • NACE MR0175, UNS S31600, S30940 and types 3a and 3b, what is the difference? - Ask our corrosion consul... https://t.co/RVKwStlMQ2, 21 hours ago
  • As per NACE MR0175, austenitic stainless steel weldments need to be solution annealed and quenched? - A... https://t.co/M0bQiZUZLD, Dec 11
Follow @oilgascorrosion ➤

Oil Prices



Oil and Gas Corrosion Ltd.
5 Smithfield
Sheffield
S3 7AR
United Kingdom
+44 (0) 114 4000850
US toll-free 877-399-1010

Privacy Policy   |   Website Terms & Conditions


© 2019 Oil & Gas Corrosion. Designed by Hunter Bevan..,.

By continuing to use the site, you agree to the use of cookies. more info

The cookie settings on this website are set to "allow cookies" to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click "Accept" below then you are consenting to this.

Close